Worcester Bosch Fault Codes

Comprehensive reference table of all Worcester Bosch boiler error codes. Click any code for detailed troubleshooting steps.

Pro Tip

Check your boiler's digital display panel (usually behind a drop-down cover) to find the current active fault code.

Error CodeDescription
EA 227No flame detected; ignition failure or lack of ionisation.
EA 229Loss of flame signal during active operation; flame extinguished.
227 VNo flame signal after ignition; burner control unit may require replacement.
228 VFlame signal detected without a physical flame present; air/gas valve fault.
E9 219Safety sensor fault; flow temperature too high, sensor open/short circuit.
E9 224Flue gas thermostat or maximum safety limit thermostat activated.
E9 276Primary flow temperature has exceeded 95°C; potential pump failure.
A1 281Pump is stuck, blocked, or running with air in the system.
C6 215Fan speed too high; check the fan harness and tachometer connector.
C7 214Fan not running during the start-up phase; electrical or mechanical failure.
C7 216Fan speed too low; check fan wiring harness.
C1 264Airflow stopped entirely during active appliance operation.
C4 273Continuous fan operation detected for the last 24 hours; appliance blocked.
D1 240Return sensor error; sensor may be wet, damaged, or short-circuited.
E2 222Central heating flow NTC sensor short-circuited or defective.
FA 306False flame fault; ionisation detected after the gas valve has closed.
F7 228Ionisation current detected before the burner has started.
9U 233Heat Control Module (HCM) or control box is defective, loose, or unplugged.
9A 362Incorrect Heat Control Module (HCM) fitted to the boiler mainboard.
360 VIncompatible code plug detected; check installation of the specific code plug.
FD 231Mains power fault; electrical power interrupted during a lockout state.
F0 238Gas valve or control box error; the gas valve internal coils require checking.
B7 257Internal control board problem or potential defect in the HCM.
D4 341Primary flow temperature is rising too fast; check system circulation.
1017 WSystem water pressure is too low; requires manual re-pressurisation.
1021 BHot water temperature sensor is defective or the plug is disconnected.
1037 WOutside temperature sensor is defective; check the connecting lead.
1065 BInternal pressure sensor is faulty, blocked with sludge, or not connected.
2927 BFlame failed during burner operation; check gas line and ionisation electrode.
815 W/BLow loss header temperature sensor faulty or installed incorrectly.
A5Internal tank negative temperature coefficient (NTC) thermistor defect.
D5Condensate pump failure; unable to discharge accumulated acidic water.