Ideal Heating Fault Codes

Comprehensive reference table of all Ideal Heating boiler error codes. Click any code for detailed troubleshooting steps.

Pro Tip

Check your boiler's digital display panel (usually behind a drop-down cover) to find the current active fault code.

Error CodeDescription
F1Low water pressure; switch has detected pressure below safe operating threshold.
F2Flame loss during operation; temporary fault preceding lockout.
L2Ignition lockout; boiler has repeatedly failed to ignite and requires manual reset.
L1Flow temperature overheat or no water flow lockout; critical heat dissipation failure.
F3Fan fault; lack of correct tachometer feedback from the fan motor.
F4 / L4Flow thermistor fault; sensor short-circuit or lead break.
F5 / L5Return thermistor fault; sensor short-circuit or lead break.
L6False flame lockout; flame detected before gas valve was commanded to open.
C0 / C2Boiler Chip Card (BCC) activation fault or calibration issue.
F9 / L9Printed Circuit Board (PCB) fault or unconfigured PCB.
LCFive boiler resets attempted within 15 minutes; system locked for safety.
F6Outside sensor failure; communication lost with weather compensation probe.
F7Low mains voltage; voltage supplied from the grid is below operational thresholds.
FUTemperature differential between flow and return is greater than 50°C; check isolation valves.
FAFlow and return pipework has been installed in reverse.
FDNo water flow detected within the system.
0System status: The boiler is in standby mode awaiting a heating or hot water demand.
CSystem status: The boiler is operating normally in central heating mode.
DSystem status: The boiler is operating normally in domestic hot water mode.